Free Field Tools
Free cheat sheets and quick-math calculators for HVACR techs. Bookmark this page and use it on the job.
Free Cheat Sheets
One-page field guides. Free to download, print and keep in the truck.
Compressor Diagnosis Checklist
Prove it failed before you change it, then find what killed it.
Download PDFA2L Refrigerant Quick Guide
R-454B and R-32: cylinders, tools and staying safe on the job.
Download PDFStartup Checklist: No Callbacks
Every check before you drive away, with a readings record.
Download PDFField Calculators
Target Superheat (Piston Systems)
For fixed-orifice (piston) systems only. TXV and EEV systems are charged by subcooling.
Formula: (3 × indoor WB − 80 − outdoor DB) ÷ 2. Always follow the manufacturer’s charging chart when one is provided.
Superheat & Subcooling
Enter the saturation temperatures from your gauges and your line temperatures.
Line-Set Charge Adjustment
How much refrigerant to add or remove for line-set length.
0.6 oz/ft is common for a 3/8″ liquid line. Use the oz/ft from the unit’s installation manual.
Duct Velocity
Limits are residential guidelines from ACCA Manual D.
Airflow from Temperature Rise
Estimate furnace airflow from output and measured temperature rise.
Formula: CFM = BTU/h output ÷ (1.08 × temperature rise). Use output, not input. Check the rise against the furnace nameplate range.
Total External Static Pressure
Add the two readings and ignore the signs. Supply: after the coil, before the first fitting. Return: between the filter and the blower.
These tools are for training and quick field estimates. Always follow the equipment manufacturer’s instructions, local codes and ACCA procedures. Want to learn the why behind the math? See the on-demand training at gilliscoach.com.